An air conditioner pulls a surprising amount of water out of the air, often several gallons a day in humid weather. That water is supposed to drip into a pan under the indoor coil and run out a drain line. When you find water on the floor next to the furnace, a stain spreading on the ceiling below an attic unit, or the system shutting off for no clear reason, the drain side has failed. We connect you with a local AC company in Terry, MS that clears drains and fixes leaks.
Where AC water comes from
As warm air passes over the cold evaporator coil, moisture condenses on the fins, the same way water beads on a cold glass. It drips into the primary drain pan and out through a PVC condensate line, usually 3/4 inch, to a floor drain, a condensate pump or outside. Attic systems usually have a secondary pan underneath with its own drain or a float switch.
Common causes of leaks
- A drain line clogged with algae, sludge or debris (the most common cause by far)
- A condensate pump that has failed or come unplugged
- A cracked or rusted-through drain pan, common on older units
- A disconnected or poorly glued drain fitting
- A frozen coil melting faster than the pan can drain
- A missing or improperly sloped trap on the drain line
If you see ice on the coil or the copper line, the leak is a symptom of something else. Our frozen evaporator coil page explains why coils ice up.
The float switch
Many systems have a safety float switch in the pan or on the drain line. When water rises, it cuts power to the thermostat circuit and the AC shuts off. If your system stopped and you also see water, the float switch is doing its job. Clearing the clog usually gets it running again, but the system shouldn't be bypassed. That cutoff is what keeps a clogged drain from turning into a ceiling collapse.
What the tech does
The tech locates the clog and clears it with a wet vacuum on the outside end of the drain or with compressed nitrogen, then flushes the line. They check the pan for cracks and rust, test the condensate pump if there is one, and confirm the float switch works. If the coil was frozen, they look for the reason: a dirty filter, a weak blower or low refrigerant.
Prevention
Many drain lines have a T-shaped access port near the indoor unit. Pouring a cup of white vinegar into it a couple of times each summer helps keep algae down. A yearly maintenance visit includes a drain flush, and keeping the coil clean with occasional coil cleaning reduces the sludge washing into the pan.
What drives the cost
A simple drain clearing costs much less than replacing a pan, a pump or a corroded coil. If water has damaged drywall or flooring, that repair is separate. Call (337) 568-0294 and we will connect you with a local AC tech serving Terry, MS.